Re: direct vent exhaust blistering paint


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by Dan on April 23, 2010 at 11:02:32:

In Reply to: Re: direct vent exhaust blistering paint posted by HeatPro on April 23, 2010 at 10:29:32:

: On some brands of direct vent, the flange is secured to the sheetmetal of the vent, instead of having the hot gas heating the siding by mounting it to the siding.

: See if the vent can be moved outward to clear the siding. The siding can be trimmed from under the flange, just to the edge so the heat has a gap behind as well. The top edge can be sealed to the remaining siding with hi-temp silicone to prevent rain and snow wetting behind.

What do you normally see as clearance around the vent pipe itself? We have over an inch. There was no info in I&O manual