[an error occurred while processing this directive]

Re: Utica Model MGB2002


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by HeatPro on June 09, 2011 at 10:00:38:

In Reply to: Utica Model MGB2002 posted by Matt on June 08, 2011 at 10:14:45:

The AFUE efficiency standards were published by GAMA since the late 1970's energy crunch. 1989 was just before all had to be 78% AFUE or better, a damper was added to reach that. If you want to up the efficiency, add the factory damper set you can get from the local supplier that carries Utica, using the factory wiring diagram from later models that have the damper.

http://books.google.com/books?id=oQAAAAAAMBAJ&pg=PA107&lpg=PA107&dq=utica+stack+damper&source=bl&ots=r2q5FbRFFX&sig=lWSrGZmE0XIU0PEHfVtTmzSBVrk&hl=en&ei=LtHwTai9EOPY0QHy2vzhBA&sa=X&oi=book_result&ct=result&resnum=3&ved=0CCsQ6AEwAg#v=onepage&q=utica%20stack%20damper&f=false