Re: Why get rid of protective rust?


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #3 ] [ FAQ ]

Posted by HeatPro on November 07, 2006 at 09:00:58:

In Reply to: Re: What cleaner can be used in old gravity radiators? posted by George on November 07, 2006 at 06:53:27:

The process that gives cast-iron radiators their long life is the self-sealing and protecting action of a rust coating so oxygen and acid can't get to the fresh iron metal under the rust layer. Cleanliness is nice; but the dirty layer of rust is better.

As suggested, flushing the loose excess is a good idea; but acid washing the rust away can make the radiator leak.