Re: Weil McClain Heat Exchanger Leaking


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by heatpro.us on March 16, 2012 at 15:40:16:

In Reply to: Weil McClain Heat Exchanger Leaking posted by Ed Hawks on March 10, 2012 at 12:12:58:

Weil-McLain sells boilers and parts through local plumbing/heating suppliers, call them for a replacement.

However, rust and age can make it difficult to change the coil without damaging the bolts to hold it; making a leaky result.

The more usual way to make the fix is to cap off the coil connections, leaving the coil inside and adding a separate indirect heating tank. You also get more hot water at better efficiency that way.

The other is to replace the boiler with a newer one with a tankless coil that is more efficient as well.