Re: Utica Boiler MGB 150HD Rev 3 Gas


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by HeatPro on July 22, 2011 at 09:30:34:

In Reply to: Utica Boiler MGB 150HD Rev 3 Gas posted by Linda on July 16, 2011 at 07:54:10:

: I have a small amount of water (maybe a 1 1/2 cups per day) coming from the overflow piper of my 15 year old boiler. It's mid July and the heat is obviously not on. I have never noticed this before. What could be wrong?

The relief valve is weeping that is supposed to keep water in until the pressure is getting high enough to cause damage. Either the pressure is close to being too high, or the valve isn't sitting correctly to keep a seal.

Call for repairs, as there is less safety, and the fresh water that is making up for the loss out the pipe has fresh oxygen in it to eat up the metal fast.