Re: Biasi boiler keeps going off


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by Jim on January 24, 2009 at 20:31:44:

In Reply to: Re: Biasi boiler keeps going off posted by Jim on January 24, 2009 at 20:29:00:

: : I have a Biasi combi boiler installed in my home and it will light pilot but switches back off after about 10 secs and shows the red "lockout light". It will re light again but the same thing happens.
: : Does anyone know what it could be?

: I have a biasi direct vent boiler. The vent also draws air in as well as exhausts. When the outside temp gets really cold frost will plug the vent where the air is drawn in. The boiler will light but stop due to lack of oxygen. When you try again it will light but stop again just as you describe, go outside clean the frost off the vent and try again.