[an error occurred while processing this directive]

Re: Looking for guidance on detaching / re-attaching steam radiators


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]

Posted by rbeck on November 11, 2008 at 08:11:21:

In Reply to: Looking for guidance on detaching / re-attaching steam radiators posted by John Burke on November 10, 2008 at 15:55:39:

Where are the leaks?
The most common causes are the packing nut which is around the stem of the valve handle, snug it up and at the union halves. This may mean the same radiator did not go back to the same room. Unions mate after a few years and need to stay mated after that. Try a little pipe dope on the face of the union without getting any dope inside the union.





Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #4 ] [ FAQ ]