Re: question for heatpro


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #3 ] [ FAQ ]

Posted by HeatPro on May 16, 2006 at 10:22:29:

In Reply to: question for heatpro posted by joe on May 16, 2006 at 09:28:43:

As discussed before, half-inch lines are not subject to gravity flow (The precaution might be about one 3/4 or larger zone pipe, but then, most installers use multiple circulators for larger zones that need much flow to use large pipes. Without specifying in which system swing-checks might be used, it is just confusing to the novice. Swing-checks can be noisy, thus, flow-control valves are recommended instead of swing-checks in residences. No, most systems don't require that instruction, especially European-style two-pipe systems.