[an error occurred while processing this directive]

Re: help choosing a boiler


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by cliff on January 16, 2007 at 12:17:57:

In Reply to: help choosing a boiler posted by Stacy Mitchell on April 12, 2004 at 14:27:54:

: I live in Maine. I have 3600 s.f. apartment building that used about 2000 gallons of heating oil last year. The 20+ year old Peerless Boiler died (cracked) a few days ago.

: Contractors all seem to have a different ideas about what to replace it with. One said get a NY Thermal boiler, described as a knock-off of Buderus, that would save perhaps 30% on oil. Priced at $6000 with a Reillo burner. Also includes some sort of outside sensing device.

: Another said this low water content boiler would not have enough water to flow through all our baseboards, causing the boiler to cycle on and off all the time, reducing its lifespan. He recommended a Peerless at $5200 with Reillo burner, and an estimated 20% savings on oil. This would include a coil to supplement my gas hot water heater (The current boiler has this coil, but first contractor said that it was probably not doing much at its advanced age and proposed that we consider expanding the NY Thermal boiler to accomodate an indirect water heater in the future).

: Any advice would be appreciated. I'm very concerned about efficiency and willing to pay more if that makes sense over the long haul. What about cold firing? Right now my boiler runs all summer to provide the supplement to the hot water heater. This seems very wasteful.

: Thanks to anyone with any guidance.

Try using a biasi boiler which is castiron and 3 pass for a maxium heating surface from burner

use a reillo burner and install a seperate indirect domestic water storage tank.
The tank ranges from 30gallon on up and is tied into the boiler. Consider it another heating zone
which runs hotwater thru a coil in the storage tank. USe a heating zone control to operate the different circulator and get one that has priority zone control. Use that for storage tank.
The boiler now will run for summer use on a cold start