Posted by HeatPro on February 28, 2005 at 11:18:37:

In Reply to: hot water heat design posted by Vicky on February 28, 2005 at 08:29:47:

You can run a one-pipe circuit overhead. Use two one-pipe tees for each radiator with the restrictions in the tees facing each other for each radiator.

http://www.heatinghelp.com/newsletter.cfm?Id=28

http://www.pmmag.com/CDA/ArticleInformation/features/BNP__Features__Item/0,2379,3657,00.html

Gravity would fight sending water downward slightly in such a design; but use of two one-pipe (diverter) tees would overcome that:

http://64.226.150.132/hydronic/onepipe/index.htm