[an error occurred while processing this directive]

Re: worcester combi boiler making noises...


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by Paul on November 16, 2004 at 15:38:41:

In Reply to: Re: worcester combi boiler making noises... posted by mitres on September 27, 2004 at 01:14:37:

"(ther's a little bicycle type valve on it)but he needs a manual to check out settings, service instructions etc, but I can't find mine, and the Bosch worcester website doesn't show any."

Strictly speaking you we need MI (manufacturers instructions) to do wrk on an appliance. However if he first lets all the air out of the expansion vessel, notes the pressure on the guage puts a bicycle pump to the vessel and pumps it up until the guage reads 0.5 to 0.75 bar more he'd be able to eliminate that part of the equation.