Re: Single water hammer bang


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by Ralph Slate on January 25, 2000 at 17:41:49:

In Reply to: Re: Single water hammer bang posted by Harold Kestenholz - Hydronic Network on January 18, 2000 at 19:53:17:

That is exactly what it was -- the single knock (and several other radiators with a few knocks during the cycle) were dragging across the wood floor as they expanded. But they didn't drag smoothly -- it was like a mini-earthquake, when enough force built up the radiator slid a little bit causing a bang.

I put some of those pads that you use on the bottom of furniture to stop it from scratching your wood floors, and the knocks went away like magic.

Ralph



Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]