[an error occurred while processing this directive]

Re: Ergomax or equivalant


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #3 ] [ FAQ ]

Posted by HeatPro on July 06, 2007 at 18:47:12:

In Reply to: Re: Ergomax or equivalant posted by Dee on July 06, 2007 at 10:24:07:

: : The mixing valve is a passive machine that makes no difference in energy.

: : The benefit of the mixing valve aside from the temperature safety is that you are mixing cold with the hot, so 2 gallons of 180 hot with 1 gallon of 70 cold makes 3 gallons per minute (180 gallons per hour capability vs 120 gph.) Thus the ability to take a shower AND fill something else.

: Thank you for your reply. I meant to say has anyone figured out how much energy is wasted in heating your potable water to the same temperature as your boiler water (through the exchanger) and then cooling it back down with a mixing valve and then proportioning it to your overall effiecency. For instance, the potable water is going to "steal" 2000 BTUs from your boiler water and then transfer that to city water via the mixing valve. I just made up the numbers but I hope it makes sense.

The question is interesting for several reasons:
1. the question as framed SEEMS to make sense to you.
a. I am interested in the thought process that makes it seem to make sense to you. As it makes sense to you, to correct it or to point out where the question goes astray can be insulting, bringing on a barrage of calling someone who replies thoroughly "an omnipotent curmudgeon, possibly manic-depressive, and a know-it-all self-aggrandizing jerk." There is nothing more amusing than someone who answers with precise science to a Dilbert Management assignment (mix unrelated concepts and give it to a committee to give a report). Make a long, winded and complicated explanation to correct you, the audience will not be disposed to listen.
b. The question is a beginning point to learn about energy and matter
(neither is destroyed) and where energy goes. Also a beginning point to learn the definition of efficiency (a problem exists in that people mix the strict definitions of 'efficiency' and 'effectiveness' to come up with half-way meanings for neither.

You can start the discussion with why you think energy is lost when you mix hot water with cool water and then make use of the mixed water. I could extent your idea to arrive at a question as to how much hot water is wasted when mixing cold water into hot coffee.


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #3 ] [ FAQ ]