Re: removal of steam radiatoe ball joint


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #3 ] [ FAQ ]

Posted by HeatPro on April 17, 2006 at 09:45:22:

In Reply to: removal of steam radiatoe ball joint posted by george on April 05, 2006 at 15:15:01:

If there is no special tool to do the job, many a stubborn fitting has been removed by cutting the nipple flush to the hole, using a jab metal blade to slice the remainder a few times the long way inside the pipe until the cut is near, but not into the threads, and then chiseling the pieces away from the threads to pull them out.