In Reply to: How do I add water into my steam furnace? posted by Bill Fletcher on March 08, 2004 at 20:52:37:

Find the 3/4in or so pipe that connects from your domestic (drinking) water pipes. There should be a valve in the line that goes to just the boiler. Open it and don't leave until you shut it. The valves on the glass are for blowing it out. Leave the two main valves open. There is a petcock below the glass that stays shut normally.