[an error occurred while processing this directive]

Re: tankless coil vs cold start ?


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by HeatPro on December 08, 2005 at 13:39:04:

In Reply to: tankless coil vs cold start ? posted by ken on December 08, 2005 at 13:35:18:

Gas boilers hardly ever make hot water inside them and residential boilers are rare today that have to be kept up in temperature to keep them from weeping between sections (your GV4 has elastomeric (rubber-like) seals between sections, so they move while keeping sealed), so they are almost all (comparatively) cold start. You wired your system for cold start, which is fine.