[an error occurred while processing this directive]

Re: old boiler


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by JohnWill65 on November 04, 2005 at 16:34:51:

In Reply to: Re: old boiler posted by HeatPro on November 02, 2005 at 16:28:37:

: Coal boilers were about 45% efficient to allow the fly ash to pass through without having to clean the exchanger every month. When the boiler had gas installed, there was no radiant heat component of the flame, so the passages alone had to absorb the heat, thus the efficiency dropped to somewhere about 30%. When gas was relatively inexpensive, it didn't matter. The plumber just wasn't old enough to know, nor used instruments to find out.

Thank you--I know then that I am making the right decision to change this to a 85% efficient unit.


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]