Re: Heatmaker HW series boiler explodes


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by HeatPro on October 21, 2005 at 20:39:42:

In Reply to: Heatmaker HW series boiler explodes posted by Jence Mandizha on October 21, 2005 at 19:09:52:

The usual cause is a dirty spark/flame sensor and/or incorrect gas pressure. Other causes can be damaged and incorrectly placed burner parts, a failing ignition control or clogged exhaust. It won't go away until all parts are reliable, in the factory-designed location and workiing as designed which takes a major disassembly, cleaning, overhaul and checkout.