[an error occurred while processing this directive]

Re: Honeywell VR8204M2701 replacement


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by HeatPro on September 14, 2005 at 23:56:39:

In Reply to: Honeywell VR8204M2701 replacement posted by Harv on September 14, 2005 at 12:57:22:

The gas valve is an OEM version also available from Williamson Thermoflo part number 511-044-354WT
http://www.williamson-thermoflo.com/pdf_files/550-110-728.pdf

It doesn't seem to have any delay, slow open, stage, or special function to differentiate it from a universal Tradeline intermittent pilot model with a propane valve blocking kit for LP.