Re: choosing gas boilers for 4 apts in building


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by HeatPro on September 05, 2005 at 19:37:36:

In Reply to: choosing gas boilers for 4 apts in building posted by john on September 05, 2005 at 17:25:13:

Heat may be supplied by a Takagi instant hot water maker if coupled to an Ergomax tank.
http://www.ergomax.com/E-Info.htm
The combination helps make a Takagi more like a conventional boiler and the Ergomax can create hot water for each apartment.

I am less enthusiastic about a Takagi providing just heat, as the load and water content in the loop is too small for stability. If you insist on just using a boiler for heat, I'd prefer a boiler with more water content as it is more forgiving of service.