You realize it's a low mass steel boiler? I wouldn't use it with a high water volume converted gravity system that could cause condensation in the boiler. I recently wanted to get one for my own home on Long Island, NY but no distributer carried it locally. Are you looking at it because of space issues? I'm getting a Burnham LE since it's readily available. I would have prefered a small cast iron 3-pass boiler like the Crown Freeport or Biasi, but the rear flue was an issue for me since the boiler had to sit further off the wall.