[an error occurred while processing this directive]

Re: Baseboard heat problem


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by Harold hydronicnetwork.net on January 23, 2004 at 17:59:20:

In Reply to: Baseboard heat problem posted by Mike on January 23, 2004 at 17:50:48:

Compare the written heat estimate for the house with the heat output of the boiler. Compare the radiation lengths in each room with the heat estimate of each room. Take the temperature of the water leaving the boiler and the water temperature coming back from each zone circuit.
http://64.226.150.132/hydronic/des/start.htm

With this information, suggestions for repair can follow.