Re: cut-in limit reached...ANSWER


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by dave_in_brooklyn on January 12, 2004 at 16:24:26:

In Reply to: Re: cut-in limit reached... posted by Harold hydronicnetwork.net on January 12, 2004 at 07:46:39:

: Sediments in the siphon loop below the pressure switch and in the pressure switch could have something to do with it. Switches get old and stray.

: Sediments in the condensate line would have more to do with low water problems.

**Turns out that the "Pig tail" connected to the "cut in" mechanism was completely clogged up with dried sluge.

I replaced it ($4.25), and I now have heat with a much lower cut in.

Thanks again