[an error occurred while processing this directive]

Re: domstic hot water from steam bioler


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by Harold hydronicnetwork.net on January 01, 2003 at 18:41:24:

In Reply to: domstic hot water from steam bioler posted by Eric Boada on January 01, 2003 at 18:29:29:

Hot water lasting only three minutes indicates that the low limit water control is not functioning to keep the water in the boiler up to 180F. Have it checked.

The water level does not have to be raised to the top of the glass gauge to compensate; drain it back down to 2/3 of the sight glass.