Posted by HeatPro on February 21, 2005 at 10:11:20:

In Reply to: Steam and Hot Water Combination posted by James on February 20, 2005 at 21:27:55:

Install a pumped flat-plate heat exchanger to make a hot water circuit for the upstairs. Water is pumped from below the boiler's water line through a heat exchanger that sends heated water upstairs with another circulator to baseboard or wall radiation. It is done frequently. Weil McLain suppliers have the exchangers available to them.