Posted by Joe Brix on February 15, 2005 at 08:11:49:

In Reply to: Oil Or Gas posted by Shideh on February 14, 2005 at 09:16:03:

Newer oil fired scotch marine designed 3 pass boilers are very quiet (Buderus, Crown Freeport, Biasi, Viessmann, etc) You could direct vent oil and gas boilers, but some complain of the noise outside and the fumes and water vapor cloud rising from the vent. If you have a chimney now, stick with it and get it lined. DIrect vent only when you have no chimney.