Strange that the pricing is all about the same.
The WM Ultra and Munchkin are condensing boilers with modulating burners, much more expensive. They can be vented with PVC pipe. The rest of the WH and Burnham line is just OK cast iron 80-85% AFUE rated. The Ultra has reset controls built in. You should get the Vision control package with the Munchkin.