If you really need to get radiator apart


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by jtown on August 20, 2001 at 08:12:08:

In Reply to: Re: Trying to get radiator apart to paint it. posted by jtown on August 20, 2001 at 04:45:25:

Sounds like you are trying to unscrew large pipe plugs from where piping can come in and out of radiators. For someone needing to separate sections to reduce the size for load, or to ease disposal: remove 1/4" threaded draw rods and then using several wooden wedges between the sections, drive them apart. Nipples will have to be gently tapped from the scrap sections to limit distortion. Goop the nipples with Permatex or such and then draw back together with shortened draw rods.



Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]