You can install Eurostyle or cast iron (Burnham)radiators in front of the Turbonics units. Water running through the 3/8 lines will provide about 7000 btuh through each radiator. The existing copper lines comprise a two-pipe system. The boiler might be able to be converted to a water boiler, if not, a new boiler can be used.