Re: Burnham Boiler


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by jtown on December 21, 2000 at 21:25:55:

In Reply to: Burnham Boiler posted by GM on December 21, 2000 at 18:52:50:

I agree with HK, I just add that I have seen lots (most) of buildings without the purge setup in question. If you can pipe the system so all air rises to an air vent for every place the piping goes up and then down (trapping air) then you just need to use the bleeders. Up north a good layout is good for that and being able to drain all the water out without low spots that will freeze. People blow compressed air through to drain them.