[an error occurred while processing this directive]

Re: HRSG Economizer Leaks


[ Follow Ups ] [ Post Followup ] [ Boilerroom.com Steam-Forum - Number 2 ] [ FAQ ]

Posted by John Ray on March 11, 2002 at 06:36:42:

In Reply to: Re: HRSG Economizer Leaks posted by Tom Stanton on March 10, 2002 at 09:27:46:

: What type of material are the economizer tubes made from and who made the boiler? Also, is it the HP, IP or LP economizer.

The IP economizer tubes are made from Carbon Steel,SA-178A. The boiler is Nooter/Erikson.
The tubes are finned



Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boilerroom.com Steam-Forum - Number 2 ] [ FAQ ]