Posted by Kyle Sexton on February 03, 2000 at 04:51:12:
In Reply to: Re: Steam Quality posted by Tony Garcia on January 26, 2000 at 23:17:40:
Sorry about that. I meant to say co-op, but I guess I must have missed it when I re-read it.
Your explanation is good, and makes sense to me. The only new thing would be the isoenthalpic process, which I can't remember doing, but the theory does works if you can keep the enthalpy the same. Thank you for the help. The original plan was to measure the quality of steam we were purchasing from our supplier and to see how efficiently we were actually using it, but depending on the costs associated with a caliometric device we may just put one on the incoming line into the plant. Thanks again for your help.