[an error occurred while processing this directive]

Re: Burnham V35 OEM specs and/or settings


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by Mark on May 18, 2005 at 19:56:14:

In Reply to: Re: Burnham V35 OEM specs and/or settings posted by HeatPro on May 07, 2005 at 15:12:52:

Thanks for the info. I was hoping to locate some literature or information. After some good old trial and error I ended up with the following results; Delavan nozzle 1.25 80 SS fired at 100 p.s.i. through an F3 head. I also verified "Z-dimension" & insertion depth of the blast tube. being that this was a retro-fit application, sealing the burner mountinting flange from unwanted secondary air was also key. I did, however end up with an 11% CO2 w/0 smoke.


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]