| Steam PSIG | Saturated Temperature | Heat of the Liquid Hf | Latent Heat Hfg | Heat of the Saturated Vapor |
|---|---|---|---|---|
| . | ||||
| 0 | 212 | 180 | 970 | 1,150 |
| 1 | 215 | 183 | 969 | 1,152 |
| 5 | 227 | 196 | 961 | 1,156 |
| 10 | 240 | 209 | 950 | 1,161 |
| 15 | 250 | 218 | 946 | 1,164 |
| 20 | 259 | 228 | 938 | 1,168 |
| 25 | 267 | 236 | 935 | 1,170 |
| 30 | 274 | 243 | 928 | 1,173 |
| 35 | 281 | 250 | 925 | 1,175 |
| 40 | 287 | 256 | 919 | 1,176 |
| 50 | 298 | 267 | 911 | 1,180 |
| 60 | 308 | 278 | 905 | 1,183 |
| 70 | 316 | 287 | 898 | 1,185 |
| 75 | 320 | 290 | 896 | 1,186 |
| 80 | 324 | 295 | 892 | 1,187 |
| 90 | 331 | 302 | 887 | 1,189 |
| 100 | 338 | 309 | 882 | 1,190 |
| 110 | 344 | 316 | 876 | 1,192 |
| 125 | 353 | 325 | 869 | 1,195 |
| 130 | 356 | 328 | 867 | 1,196 |
| 140 | 361 | 333 | 862 | 1,196 |
| 150 | 366 | 339 | 858 | 1,197 |
| 160 | 371 | 344 | 854 | 1,198 |
| 170 | 375 | 348 | 850 | 1,198 |
| 175 | 377 | 351 | 848 | 1,199 |
| 180 | 380 | 353 | 846 | 1,199 |
| 190 | 384 | 358 | 842 | 1,200 |
| 200 | 388 | 362 | 838 | 1,201 |
| 225 | 397 | 372 | 830 | 1,202 |
| 250 | 406 | 381 | 821 | 1,203 |
| 275 | 414 | 391 | 813 | 1,204 |
| 300 | 421 | 398 | 806 | 1,204 |
| 325 | 429 | 407 | 798 | 1,205 |
| 350 | 436 | 414 | 791 | 1,205 |
| 375 | 442 | 421 | 784 | 1,205 |
| 400 | 448 | 428 | 778 | 1,205 |